Huawei S6730-S48X6Q (48*10GE SFP+ ports, 6*40GE QSFP+ ports, without power module) PN.02355UUS
Memory: 4 GB
Flash memory: 2 GB in total. To view the available flash memory size, run the display version command.
Note:
A QSFP+ optical port cannot be split into four 10GE ports.
In V200R024C00 and later versions, a 100GE RTU license can be used to upgrade the port rate to 100 Gbit/s.
Huawei CloudEngine S6730-S series full-featured 10 GE switches are Huawei's new generation fixed switches ,to provide 10GE downlink ports as well as 40/100GE uplink ports.
Huawei CloudEngine S6730-S can be used to provide high-speed access for 10 Gbit/s access to high-density servers orfunction as a core/aggregation switch on a campus network to provide 40 Gbit/s rate. In addition, S6730-S provides a wide variety of services, comprehensive security policies, and various QoS features to help customers build scalable, manageable,reliable, and secure campus and data center networks.
| Item | Specification |
|---|---|
| Dimensions without packaging (H x W x D) [mm(in.)] |
Basic dimensions (excluding the parts protruding from the body): 43.6 mm x 442.0 mm x 420.0 mm (1.72 in. x 17.40 in. x 16.54 in.) Maximum dimensions (the depth is the distance from ports on the front panel to the parts protruding from the rear panel): 43.6 mm x 442.0 mm x 446.0 mm (1.72 in. x 17.40 in. x 17.56 in.) |
| Dimensions with packaging (H x W x D) [mm(in.)] | 175.0 mm x 650.0 mm x 550.0 mm (6.89 in. x 25.59 in. x 21.65 in.) |
| Chassis height [U] | 1 U |
| Chassis material | Metal |
| Weight without packaging [kg(lb)] | 5.84 kg (12.87 lb) |
| Weight with packaging [kg(lb)] | 9.2 kg (20.28 lb) |
| Typical power consumption [W] | 30% traffic under the ATIS standard and dual power modules: 158.3 W |
| Typical heat dissipation [BTU/hour] | 30% traffic under the ATIS standard and dual power modules: 540.14 |
| Maximum power consumption [W] |
High temperature 45°C (113°F), 100% traffic, and dual power modules: 177.5 W High temperature 45°C (113°F), 100% traffic, long-distance optical module, 100% fan speed, and dual power modules: 259.5 W |
| Maximum heat dissipation [BTU/hour] |
High temperature 45°C (113°F), 100% traffic, and dual power modules: 605.65 High temperature 45°C (113°F), 100% traffic, long-distance optical module, 100% fan speed, and dual power modules: 885.44 |
| Static power consumption [W] | 88 W |
| MTBF [years] | 56.87 years |
| Availability | > 0.99999 |
| Noise at normal temperature (acoustic power) [dB(A)] | 65 dB(A) |
| Noise at normal temperature (acoustic pressure) [dB(A)] | 52 dB(A) |
| Number of card slots | 0 |
| Number of power slots | 2 |
| Number of fans modules | 4 |
| Redundant power supply |
1+1 Pluggable AC and DC power modules can be used together in the same switch. |
| Long-term operating temperature [°C(°F)] | –5°C to +45°C (23°F to 113°F) at an altitude of 0 to 1800 m (0 to 5905.44 ft.) |
| Restriction on the operating temperature variation rate [°C(°F)] |
When the altitude is 1800–5000 m (5906–16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). Devices cannot start when the temperature is lower than 0°C (32°F). When the QSFP-100G-ER4 optical module is used, the operating temperature ranges from -5°C to +40°C (23°F to 104°F). |
| Storage temperature [°C(°F)] | –40°C to +70°C (–40°F to +158°F) |
| Long-term operating relative humidity [RH] | 5% RH to 95% RH, non-condensing |
| Long-term operating altitude [m(ft.)] | 0–5000 m (0–16404 ft.) |
| Storage altitude [m(ft.)] | 0-5000 m (0-16404 ft.) |
| Power supply mode | Pluggable power supply |
| Rated input voltage [V] |
|
| Input voltage range [V] |
|
| Maximum input current [A] | The current specifications are related to the pluggable power module. For details, see Pluggable Power Modules. |
| Memory | 4 GB |
| Flash memory | 2 GB in total. To view the available flash memory size, run the display version command. |
| Console port | RJ45 |
| Eth Management port | RJ45 |
| USB | Supported |
| RTC | Supported |
| RPS input | Not supported |
| Service port surge protection [kV] | - |
| Power supply surge protection [kV] |
|
| Ingress protection level (dustproof/waterproof) | IP20 |
| Types of fans | Pluggable |
| Heat dissipation mode | Air cooling for heat dissipation, intelligent fan speed adjustment |
| Airflow direction | Air intake from front, air exhaustion from rear (front-to-rear) |
| PoE | Not supported |
| Certification |
EMC certification Safety certification Manufacturing certification |