Huawei S5720-28X-SI-24S-AC Switch
Review: 5 - "A masterpiece of literature" by , written on May 4, 2006
I really enjoyed this book. It captures the essential challenge people face as they try make sense of their lives and grow to adulthood.

Huawei S5720-28X-SI-24S-AC Switch

  • Brand New Condition
  • Original Box Packed
  • Latest Firmware Version
Image
Available:In Stock
$0.00

Huawei S5720-28X-SI-24S-AC switch with 24-port GE SFP, including 8-port 1000BASE-T combo, 4-port 10GE SFP+, 1 AC power

Forwarding performance: 96Mpps

Switching capacity: 336Gbps

By default, a combo port works in auto mode, in which the port type is determined as follows: You can configure a combo port as an electrical or optical port using the combo-port command.

  • If the optical port has no optical module installed and the electrical port has no Ethernet cable connected, the port type depends on which port is connected first. If the electrical port is connected by an Ethernet cable first, the electrical port is used for data switching. If the optical port has an optical module installed first, the optical port is used for data switching.
  • If the electrical port has an Ethernet cable connected and is in Up state, the electrical port is still used for data switching when the optical port has an optical module installed.
  • If the optical port, no matter in Up or Down state, has an optical module installed, the optical port is still used for data switching when the electrical port has an Ethernet cable connected.
  • If the optical port has an optical module installed and the electrical port has an Ethernet cable connected, the optical port is used for data switching after the switch restarts.

Huawei S5720-SI Flexible Gigabit Ethernet switches that provide resilient, high-density Layer 3 switching for data centers. Features include multiple-terminals, HD video security, and video conferencing applications. Intelligent iStack clustering, 10 Gbit/s upstream ports and IPv6 forwarding enable use as aggregation switches in enterprise campus networks.

Next-generation reliability, security, and energy-saving technologies make S5720-SI Series Switches easy to install and maintain, and an excellent source of low Total Cost of Ownership (TCO).

 

Item Description
Fixed port 24 Gig SFP, 8 combo 10/100/1000Base-T Ethernet ports, 4 10 Gig SFP+
Forwarding performance 96 Mpps
Extended slot NA
MAC address table IEEE 802.1d
16K MAC address entries
MAC address learning and aging
Static, dynamic, and blackhole MAC address entries
Packet filtering based on source MAC addresses
VLAN 4K VLANs
Guest VLAN and voice VLAN
GVRP
MUX VLAN
VLAN assignment based on MAC addresses, protocols, IP subnets, policies, and ports
1:1 and N:1 VLAN Mapping
IP routing Static routes, RIPv1/2、RIPng、OSPF、OSPFv3、ECMP、ISIS、ISISv6、BGP、BGP4+、VRRP、VRRP6
IPv6 features Neighbor Discovery (ND)
Path maximum transmission unit (PMTU)
IPv6 Ping, IPv6 Tracert, and IPv6 Telnet
6 to4 tunnel, ISATAP tunnel, and manually configur ed tunnel
Multicast forwarding IGMP v1/v2/v3 snooping and IGMP fast leave
Multicast forwarding in a VLAN and multicast replication between VLANs
Multicast load balancing among member ports of a trunk
Controllable multicast
Port-based multicast traffic statistics collection
MLD v1/v2、MLD v1/v2 Snooping
Multicast Dense Mode (PIM-DM), and Protocol Independent Multicast Source-Specific Multicast (PIM-SSM)
Multicast Source Discovery Protocol (MSDP)
QoS/ACL Traffic classification based on ACLs
Configuring traffic classification priorities
Traffic shaping on an egress interface
Traffic filtering, Traffic policing (CAR), Modifying the packet   priorities, Modifying the simple domains of packets, Modifying the packet VLANs
Priority Queuing (PQ), Weighted Deficit Round Robin (WDRR), PQ+WDRR, Weighted Round Robin (WRR), PQ+WRR
Basic IPv4 ACL, Advanced IPv4 ACL, Basic IPv6 ACL, Advanced IPv6 ACL, Layer 2 ACL, User-defined ACL
Number of rules per IPv4 ACL: 2K
Number of rules per IPv6 ACL: 2K
Security features Hierarchical user management and password protection
DoS attack defense, ARP attack defense, and ICMP attack defense
Binding of the IP address, MAC address, interface number, and VLAN ID of a user
Port isolation, port security, and sticky MAC
MAC Forced Forwarding (MFF)
Blackhole MAC address entries
Limit on the number of learned MAC addresses
IEEE 802.1x authentication and the limit on the number of users on an interface
AAA authentication, RADIUS authentication, HWTACACS+ authentication, and NAC SSH v2.0
Hypertext Transfer Protocol Secure (HTTPS)
CPU defense; Blacklist and whitelist
Reliability Service interface-based stacking
Maximum number of stacked devices: 9
Stack bandwidth (Unidirectional): Up to 48 Gbit/s
VRRP standard protocol
Management and
Maintenance
Virtual cable test, SNMP v1/v2c/v3, RMON
Network management system (NMS) and Web managemen
System logs and multi-level alarms
802.3az EEE
sFlow
iStack
Interoperability VLAN-Based Spanning Tree (VBST), working with PVST, PVST+, and RPVST
Link-type Negotiation Protocol (LNP), similar with DTP
VLAN Central Management Protocol (VCMP), similar with VTP
Operating environment Operating temperature: 0-1800 m altitude: 0-45℃

 1800-5000m altitude: The operating temperature reduces by 1oC every time the altitude increases by 220m.

Relative humidity: 5% to 95% (noncondensing)

Input voltage AC: Rated voltage range: 100 V to 240 V AC, 50/60 Hz

Maximum voltage range: 90 V to 264 V AC, 47/63 Hz

DC: Rated voltage range: –48 V to –60 V, DC

Maximum voltage range: –36 V to –72 V, DC

Maximum input current 3 A
Maximum power consumption of the device AC: 41.7 W

 

DC: 42.7W

Dimensions (H x D x W mm) 43.6 x 442.0 x 224.8
PN. 98010625

Huawei S5720-28X-SI-24S-AC switch with 24-port GE SFP, including 8-port 1000BASE-T combo, 4-port 10GE SFP+, 1 AC power

Forwarding performance: 96Mpps

Switching capacity: 336Gbps

By default, a combo port works in auto mode, in which the port type is determined as follows: You can configure a combo port as an electrical or optical port using the combo-port command.

  • If the optical port has no optical module installed and the electrical port has no Ethernet cable connected, the port type depends on which port is connected first. If the electrical port is connected by an Ethernet cable first, the electrical port is used for data switching. If the optical port has an optical module installed first, the optical port is used for data switching.
  • If the electrical port has an Ethernet cable connected and is in Up state, the electrical port is still used for data switching when the optical port has an optical module installed.
  • If the optical port, no matter in Up or Down state, has an optical module installed, the optical port is still used for data switching when the electrical port has an Ethernet cable connected.
  • If the optical port has an optical module installed and the electrical port has an Ethernet cable connected, the optical port is used for data switching after the switch restarts.

Huawei S5720-SI Flexible Gigabit Ethernet switches that provide resilient, high-density Layer 3 switching for data centers. Features include multiple-terminals, HD video security, and video conferencing applications. Intelligent iStack clustering, 10 Gbit/s upstream ports and IPv6 forwarding enable use as aggregation switches in enterprise campus networks.

Next-generation reliability, security, and energy-saving technologies make S5720-SI Series Switches easy to install and maintain, and an excellent source of low Total Cost of Ownership (TCO).

 

Item Description
Fixed port 24 Gig SFP, 8 combo 10/100/1000Base-T Ethernet ports, 4 10 Gig SFP+
Forwarding performance 96 Mpps
Extended slot NA
MAC address table IEEE 802.1d
16K MAC address entries
MAC address learning and aging
Static, dynamic, and blackhole MAC address entries
Packet filtering based on source MAC addresses
VLAN 4K VLANs
Guest VLAN and voice VLAN
GVRP
MUX VLAN
VLAN assignment based on MAC addresses, protocols, IP subnets, policies, and ports
1:1 and N:1 VLAN Mapping
IP routing Static routes, RIPv1/2、RIPng、OSPF、OSPFv3、ECMP、ISIS、ISISv6、BGP、BGP4+、VRRP、VRRP6
IPv6 features Neighbor Discovery (ND)
Path maximum transmission unit (PMTU)
IPv6 Ping, IPv6 Tracert, and IPv6 Telnet
6 to4 tunnel, ISATAP tunnel, and manually configur ed tunnel
Multicast forwarding IGMP v1/v2/v3 snooping and IGMP fast leave
Multicast forwarding in a VLAN and multicast replication between VLANs
Multicast load balancing among member ports of a trunk
Controllable multicast
Port-based multicast traffic statistics collection
MLD v1/v2、MLD v1/v2 Snooping
Multicast Dense Mode (PIM-DM), and Protocol Independent Multicast Source-Specific Multicast (PIM-SSM)
Multicast Source Discovery Protocol (MSDP)
QoS/ACL Traffic classification based on ACLs
Configuring traffic classification priorities
Traffic shaping on an egress interface
Traffic filtering, Traffic policing (CAR), Modifying the packet   priorities, Modifying the simple domains of packets, Modifying the packet VLANs
Priority Queuing (PQ), Weighted Deficit Round Robin (WDRR), PQ+WDRR, Weighted Round Robin (WRR), PQ+WRR
Basic IPv4 ACL, Advanced IPv4 ACL, Basic IPv6 ACL, Advanced IPv6 ACL, Layer 2 ACL, User-defined ACL
Number of rules per IPv4 ACL: 2K
Number of rules per IPv6 ACL: 2K
Security features Hierarchical user management and password protection
DoS attack defense, ARP attack defense, and ICMP attack defense
Binding of the IP address, MAC address, interface number, and VLAN ID of a user
Port isolation, port security, and sticky MAC
MAC Forced Forwarding (MFF)
Blackhole MAC address entries
Limit on the number of learned MAC addresses
IEEE 802.1x authentication and the limit on the number of users on an interface
AAA authentication, RADIUS authentication, HWTACACS+ authentication, and NAC SSH v2.0
Hypertext Transfer Protocol Secure (HTTPS)
CPU defense; Blacklist and whitelist
Reliability Service interface-based stacking
Maximum number of stacked devices: 9
Stack bandwidth (Unidirectional): Up to 48 Gbit/s
VRRP standard protocol
Management and
Maintenance
Virtual cable test, SNMP v1/v2c/v3, RMON
Network management system (NMS) and Web managemen
System logs and multi-level alarms
802.3az EEE
sFlow
iStack
Interoperability VLAN-Based Spanning Tree (VBST), working with PVST, PVST+, and RPVST
Link-type Negotiation Protocol (LNP), similar with DTP
VLAN Central Management Protocol (VCMP), similar with VTP
Operating environment Operating temperature: 0-1800 m altitude: 0-45℃

 1800-5000m altitude: The operating temperature reduces by 1oC every time the altitude increases by 220m.

Relative humidity: 5% to 95% (noncondensing)

Input voltage AC: Rated voltage range: 100 V to 240 V AC, 50/60 Hz

Maximum voltage range: 90 V to 264 V AC, 47/63 Hz

DC: Rated voltage range: –48 V to –60 V, DC

Maximum voltage range: –36 V to –72 V, DC

Maximum input current 3 A
Maximum power consumption of the device AC: 41.7 W

 

DC: 42.7W

Dimensions (H x D x W mm) 43.6 x 442.0 x 224.8
PN. 98010625

GLOBAL SHIPPING
XponShop offers you various options of shipping ways:
-EXW SHENZHEN
-Overseas Express which includes shipping by Carriers, by Air Cargo, and Sea Freight.

Cargo Weight/Volume Suggested Shipping Ways Comments
≤ 45KGS By Shipping Carriers (DHL, UPS, FedEx, etc.) Door to door service, fast and convenient.
>45KGS By Air Cargo Door to airport service, more cost-efficient.
1CBM By Sea Freight Large-volume goods, door to seaport service, longer shipping time but cheaper.

XponShop makes the most commonly used trade terms available for your convenience: CNF, CPT, CIF, DDP, etc to ensure global fast and convenient delivery.
Once you confirm your order, you may contact XponShop team for calculating the freight charges and choose the optimal shipping way.
NOTE:
· Shipping may be subject to local taxes or duties; XponShop is not responsible for and has no control over these charges.
· No matter which shipping ways you chose, cargo insurance is highly recommended in case of unpredictable loss.

RETURN POLICY
We aim to deliver products for your appreciation and satisfaction. XponShop return or replacement policy applies only if the product is damaged or incorrectly delivered.
–If you receive a damaged product or it is different from the one requested, you can return or replace it within 7 days of receipt. In such a case, costs shall be borne by XponShop.
–If the product is malfunctional during use and under 12 months warranty, XponShop support team will contact you to troubleshoot the issue by professional diagnosis. The unsolvable problem will trigger the return procedure: repair, replace and reship to you or refund if repair or replacement is inapplicable.
NOTE:
· Please be aware that the product must be returned to the specified address as defined by shipping incoterms against the sales invoice/contract.
· For further information about how to return products, please contact our XponShop team at sales@xponshop.com, we will advise you on how to proceed.

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)