Huawei S5730-68C-SI-AC Switch
- Brand New Condition
- Original Box Packed
- Latest Firmware Version
- Category:Huawei,Huawei Switch,S5700 Series
Huawei S5730-68C-SI-AC switch with 48-port 1000BASE-T, 4-port 10GE SFP+, 2 power slots PN#98010713
Forwarding performance: 240 Mpps
Switching capacity: 680Gbps
32K MAC address entries
With 1 extension slot
PoE Not Supported
Item | Description |
Fixed ports | 48×10/ 100/1000 Base-T, 4×10 Gig SFP+ |
MAC address table | 32K MAC |
Dimensions mm (W×D ×H) | 442× 420× 44.4 |
Slot | One extended slot that supports an interface card:4*40 GE QSFP+ interface card |
Input voltage | AC: Rated AC voltage: 100-240V AC;50/60Hz Max AC voltage: 90-264V AC;47-63Hz;
DC: Rated DC power: -48- -60V DC Max DC voltage: -36- -72V DC |
Maximum power consumption | 65.4W(Without card) |
Typical power consumption (Without PD) | 42.3W (Without card) |
Operating temperature | 0 m-1800 m altitude:0-45°C(long term);-5°C to 50°C (short term) 1800-5000 m altitude: The operating temperature reduces by 1°C every time the altitude increases by 220 m |
Relative humidity | 5% to 95% (non-condensing) |
Heat dissipation | Heat dissipation using fans supporting intelligent speed adjustment |
MAC address table | IEEE 802.1d compliance
32K MAC address entries MAC address learning and aging Static, dynamic, and blackhole MAC address entries Packet filtering based on source MAC addresses |
VLAN | 4K VLANs
Guest VLAN and voice VLAN GVRP MUX VLAN VLAN assignment based on MAC addresses, protocols, IP subnets, policies, and ports 1:1 and N:1 VLAN mapping |
Reliability | RRPP ring topology and RRPP multi-instance
Smart Link tree topology and Smart Link multi-instance, providing millisecond-level protection switchover SEP STP (IEEE 802.1d), RSTP (IEEE 802.1w), and MSTP (IEEE 802.1s) ERPS (G.8032) BPDU protection, root protection, and loop protection |
Interoperability | VLAN-Based Spanning Tree (VBST), working with PVST, PVST+, and RPVST
Link-type Negotiation Protocol (LNP), similar to DTP VLAN Central Management Protocol (VCMP), similar to VTP |
IP routing | Static route, RIPv1/v2, RIPng, OSPF, OSPFv3, ECMP, IS-IS, IS-ISv6, BGP, BGP4+, VRRP, and VRRP6 |
Multicast | PIM DM, PIM SM, PIM SSM
IGMP v1/v2/v3,IGMP v1/v2/v3 snooping and IGMP fast leave MLD v1/v2 and MLD v1/v2 snooping Multicast forwarding in a VLAN and multicast replication between VLANs Multicast load balancing among member ports of a trunk Controllable multicast Port-based multicast traffic statistics |
IPv6 features | Neighbor Discovery (ND)
Path MTU (PMTU) IPv6 ping, IPv6 tracert, and IPv6 Telnet 6to4 tunnel, ISATAP tunnel, and manually configured tunnel ACLs based on the source IPv6 address, destination IPv6 address, Layer 4 ports, or protocol type |
QoS/ACL | Rate limiting on packets sent and received by a port
Packet redirection Port-based traffic policing and two-rate three-color CAR Eight queues on each port WRR, DRR, SP, WRR+SP, and DRR+SP queue scheduling algorithms Re-marking of the 802.1p priority and DSCP priority Packet filtering at Layer 2 to Layer 4, filtering out invalid frames based on the source MAC address, destination MAC address, source IP address, destination IP address, TCP/UDP port number, protocol type, and VLAN ID Rate limiting in each queue and traffic shaping on ports |
Security | Hierarchical user management and password protection DoS attack defense, ARP attack defense, and ICMP attack defense
Binding of the IP address, MAC address, port number, and VLAN ID of a user Port isolation, port security, and sticky MAC MFF Blackhole MAC address entries Limit on the number of learned MAC addresses IEEE 802.1x authentication and limit on the number of users on a port AAA authentication, RADIUS authentication, HWTACACS authentication, and NAC SSH v2.0 HTTPS CPU defense Blacklist and whitelist IEEE 802.1x authentication, MAC address authentication, and Portal authentication DHCPv4/v6 client/relay/server/snooping Attack source tracing and punishment for IPv6 packets such as ND, DHCPv6, and MLD packets |
SVF | Plug-and-play SVF client Automatic software and patch loading to clients
One-click and automatic delivery of service configurations Independent client running |
OAM | Software OAM:
EFM OAM CFM OAM Y.1731 performance test |
Management and maintenance | iStack
Virtual cable test SNMP v1/v2c/v3 RMON Web-based NMS System logs and alarms of different levels 802.3az EEE sFlow |
Interoperability | Supports VBST (Compatible with PVST/PVST+/RPVST) Supports LNP (Similar to DTP)
Supports VCMP (Similar to VTP) |
Huawei S5730-68C-SI-AC switch with 48-port 1000BASE-T, 4-port 10GE SFP+, 2 power slots PN#98010713
Forwarding performance: 240 Mpps
Switching capacity: 680Gbps
32K MAC address entries
With 1 extension slot
PoE Not Supported
The S5730-SI series switches (S5730-SI for short) are next-generation standard gigabit Layer 3 Ethernet switches. They can be used as an access or aggregation switch on a campus network or as an access switch in a data center. The S5730-SI series switches provide flexible full gigabit access and cost-effective fixed GE/10 GE uplink ports. Meanwhile, the S5730-SI can provide 4 x 40 GE uplink ports with an interface card.
Item | Description |
Fixed ports | 48×10/ 100/1000 Base-T, 4×10 Gig SFP+ |
MAC address table | 32K MAC |
Dimensions mm (W×D ×H) | 442× 420× 44.4 |
Slot | One extended slot that supports an interface card:4*40 GE QSFP+ interface card |
Input voltage | AC: Rated AC voltage: 100-240V AC;50/60Hz Max AC voltage: 90-264V AC;47-63Hz;
DC: Rated DC power: -48- -60V DC Max DC voltage: -36- -72V DC |
Maximum power consumption | 65.4W(Without card) |
Typical power consumption (Without PD) | 42.3W (Without card) |
Operating temperature | 0 m-1800 m altitude:0-45°C(long term);-5°C to 50°C (short term) 1800-5000 m altitude: The operating temperature reduces by 1°C every time the altitude increases by 220 m |
Relative humidity | 5% to 95% (non-condensing) |
Heat dissipation | Heat dissipation using fans supporting intelligent speed adjustment |
MAC address table | IEEE 802.1d compliance
32K MAC address entries MAC address learning and aging Static, dynamic, and blackhole MAC address entries Packet filtering based on source MAC addresses |
VLAN | 4K VLANs
Guest VLAN and voice VLAN GVRP MUX VLAN VLAN assignment based on MAC addresses, protocols, IP subnets, policies, and ports 1:1 and N:1 VLAN mapping |
Reliability | RRPP ring topology and RRPP multi-instance
Smart Link tree topology and Smart Link multi-instance, providing millisecond-level protection switchover SEP STP (IEEE 802.1d), RSTP (IEEE 802.1w), and MSTP (IEEE 802.1s) ERPS (G.8032) BPDU protection, root protection, and loop protection |
Interoperability | VLAN-Based Spanning Tree (VBST), working with PVST, PVST+, and RPVST
Link-type Negotiation Protocol (LNP), similar to DTP VLAN Central Management Protocol (VCMP), similar to VTP |
IP routing | Static route, RIPv1/v2, RIPng, OSPF, OSPFv3, ECMP, IS-IS, IS-ISv6, BGP, BGP4+, VRRP, and VRRP6 |
Multicast | PIM DM, PIM SM, PIM SSM
IGMP v1/v2/v3,IGMP v1/v2/v3 snooping and IGMP fast leave MLD v1/v2 and MLD v1/v2 snooping Multicast forwarding in a VLAN and multicast replication between VLANs Multicast load balancing among member ports of a trunk Controllable multicast Port-based multicast traffic statistics |
IPv6 features | Neighbor Discovery (ND)
Path MTU (PMTU) IPv6 ping, IPv6 tracert, and IPv6 Telnet 6to4 tunnel, ISATAP tunnel, and manually configured tunnel ACLs based on the source IPv6 address, destination IPv6 address, Layer 4 ports, or protocol type |
QoS/ACL | Rate limiting on packets sent and received by a port
Packet redirection Port-based traffic policing and two-rate three-color CAR Eight queues on each port WRR, DRR, SP, WRR+SP, and DRR+SP queue scheduling algorithms Re-marking of the 802.1p priority and DSCP priority Packet filtering at Layer 2 to Layer 4, filtering out invalid frames based on the source MAC address, destination MAC address, source IP address, destination IP address, TCP/UDP port number, protocol type, and VLAN ID Rate limiting in each queue and traffic shaping on ports |
Security | Hierarchical user management and password protection DoS attack defense, ARP attack defense, and ICMP attack defense
Binding of the IP address, MAC address, port number, and VLAN ID of a user Port isolation, port security, and sticky MAC MFF Blackhole MAC address entries Limit on the number of learned MAC addresses IEEE 802.1x authentication and limit on the number of users on a port AAA authentication, RADIUS authentication, HWTACACS authentication, and NAC SSH v2.0 HTTPS CPU defense Blacklist and whitelist IEEE 802.1x authentication, MAC address authentication, and Portal authentication DHCPv4/v6 client/relay/server/snooping Attack source tracing and punishment for IPv6 packets such as ND, DHCPv6, and MLD packets |
SVF | Plug-and-play SVF client Automatic software and patch loading to clients
One-click and automatic delivery of service configurations Independent client running |
OAM | Software OAM:
EFM OAM CFM OAM Y.1731 performance test |
Management and maintenance | iStack
Virtual cable test SNMP v1/v2c/v3 RMON Web-based NMS System logs and alarms of different levels 802.3az EEE sFlow |
Interoperability | Supports VBST (Compatible with PVST/PVST+/RPVST) Supports LNP (Similar to DTP)
Supports VCMP (Similar to VTP) |
GLOBAL SHIPPING
XponShop offers you various options of shipping ways:
-EXW SHENZHEN
-Overseas Express which includes shipping by Carriers, by Air Cargo, and Sea Freight.
Cargo Weight/Volume | Suggested Shipping Ways | Comments |
≤ 45KGS | By Shipping Carriers (DHL, UPS, FedEx, etc.) | Door to door service, fast and convenient. |
>45KGS | By Air Cargo | Door to airport service, more cost-efficient. |
>1CBM | By Sea Freight | Large-volume goods, door to seaport service, longer shipping time but cheaper. |
XponShop makes the most commonly used trade terms available for your convenience: CNF, CPT, CIF, DDP, etc to ensure global fast and convenient delivery.
Once you confirm your order, you may contact XponShop team for calculating the freight charges and choose the optimal shipping way.
NOTE:
· Shipping may be subject to local taxes or duties; XponShop is not responsible for and has no control over these charges.
· No matter which shipping ways you chose, cargo insurance is highly recommended in case of unpredictable loss.
RETURN POLICY
We aim to deliver products for your appreciation and satisfaction. XponShop return or replacement policy applies only if the product is damaged or incorrectly delivered.
–If you receive a damaged product or it is different from the one requested, you can return or replace it within 7 days of receipt. In such a case, costs shall be borne by XponShop.
–If the product is malfunctional during use and under 12 months warranty, XponShop support team will contact you to troubleshoot the issue by professional diagnosis. The unsolvable problem will trigger the return procedure: repair, replace and reship to you or refund if repair or replacement is inapplicable.
NOTE:
· Please be aware that the product must be returned to the specified address as defined by shipping incoterms against the sales invoice/contract.